ADVANCES IN POLAR SCIENCE ›› 1994, Vol. 5 ›› Issue (1-English): 11-19.

• Contents • Previous Articles     Next Articles

Deep electrical conductivity structure in the Great Wall Station area, Fildes Peninsula, West Antarctica

Kong Xiangru, Zhang Jianjun   

  1. Institute of Geophysics, Academia Sinica, Beijing 100101, China
  • Online:1944-03-30 Published:1944-03-30
  • Contact: Kong Xiangru

Abstract:

MT measured in Great Wall Station area shows that the electrical conductivity major axis of the Wind Valley Fault is 110°NE and the crustal thickness in the Fildes Peninsula is about 22. 3 km. The crust contains four main resistivity layers with their thicknesses being 1. 3 km, 6. 7 km, 1. 2 km and 13.1 km respectively. The upper crustal thickness is 9. 2 km and the lower crustal thickness is 13. 1 km.